Please make sure to drain current oil and replace drain cap before flushing oil is used.
Remove the fill cap.
Add flushing oil until the level is at the half-way mark on the sight glass. Replace fill cap.
Run the pump by either opening and closing the lid, or manually pressing the micro switch located at the back right of the chamber.
After 15-20 cycles, the pump should be warm and the oil should have been circulated through out. The more cycles ran, the better the oil can flush the moving parts of the pump.
If the flushing oil becomes thick or milky during this process, please drain and refill with new flushing oil. Once the flushing oil that is drained after completing a flush looks similar to the oil that was added, it is more than likely clean.
Remove drain plug and drain flushing oil from the pump. Replace drain plug.
Remove fill plug and refill with operating oil. Replace fill plug and reassemble.
The conditioning program ensures that the pump is thoroughly rinsed. During the program the pump and oil reaches operating temperature so that the oil can better absorb any moisture and contaminants and filter them. The high temperature enables any moisture in the pump to evaporate minimizing the risk for corrosion in the pump.
MVS20:
The program lasts 15 minutes and it is advisable to run it at least once a week. Turn on the machine, press the key conditioning program and close the lid. The program runs automatically. During the program the display will show moving dots. The program can be interrupted at any time using the stop key. It is important for the program to complete a full 15 minute cycle and advisable to only interrupt the cycle for something urgent.
X Models:
Use P09- Set the vacuum at 99.9% and Extra Vacuum to E30.
Run machine for 5-10 cycles to warm up the pump assembly and help burn off and filter contaminants.
XP Models:
Toggle to the second page in program 1 by using the "S" button, where you will see advanced functions "VE SA CP AS SI IC LT" along the bottom of the display. Use the down arrow to highlight CP and press the left or right arrow key. This should add an "X" underneath the CP option. Close the lid and this will start a 4 minute condition cycle.
Minipack does not assume any responsibility or liability for the advice given and shall not be liable for any direct, indirect, special, incidental or consequential damages in connection with the use of this information.